20

HOLD A MAGNET TO THE RESET SWITCH AND
MAKE SURE ALL LEDS ILLUMINATE WHEN
MAGNET IS PRESENT

REPEAT STARTUP, IF
TESTING RETURNS TO THIS
PLACE TWICE, REPLACE
THE EC-11

CONTROLLER

CHECK DASH WIRING AND

CONNECTORS. CONSULT

VEHICLE MANUAL FOR

FURTHER TROUBLE-

SHOOTING INFORMATION.

REPAIR/REPLACE AS

NECESSARY AND REPEAT

STARTUP.

TURN IGNITION OFF. CHECK FOR
CONTINUITY BETWEEN PIN D
AND ITS TERMINAL ON THE DASH
LIGHT RELAY.

YES

HOLD MAGNET
HERE TO RESET

REMOVE MAGNET

NO

ALL LEDS

SHOULD

BE ON

REPAIR/REPLACE WIRE

HARNESS. RECONNECT 14

PIN CONNECTOR AND

REPEAT STARTUP.

REPLACE EC-11

CONTROLLER

REPEAT STARTUP

RECONNECT 14 PIN
CONNECTOR. TURN

IGNITION ON AND CHECK

FOR POWER AT THE DASH

LIGHT RELAY COIL.

CONNECT OPPOSITE END
OF RELAY COIL TO
GROUND AND NOTE
REACTION OF DASH
LIGHT.

REPLACE RELAY

NO POWER

POWER

LEDS ILLUMINATED?

REMOVE MAGNET

REPEAT STARTUP

DASH LIGHT ON

DASH LIGHT OFF

NO CONTINUITY

CONTINUITY

TROUBLESHOOTING

SECTION VII PART B - TESTING FOR FALSE FAILURE CAUSED BY DASH LIGHT RELAY

BW1671 © 2004 Bendix Commercial Vehicle Systems LLC All rights reserved. 4/2004 Printed in U.S.A.

CHECK FOR
POWER HERE

FROM PIN D

COIL

RELAY

LIGHT

GROUND THIS
WIRE

COIL

RELAY

IF LIGHT IS

ON - BAD

RELAY

Advertising