2

FIGURE 2 - TYPICAL R-12P

PILOT RELAY VALVE SYSTEM SCHEMATIC

DELIVERY

SPRING

BRAKE

VALVE

SUPPLY

SERVICE RELAY

VALVE

QUICK

RELEASE

VALVE

VENTED

CUT-OUT

COCK

SINGLE

CHECK VALVE

VENTED

CUT-OUT

COCK

RESERVOIR

CONTROL

BRAKE CHAMBER

SLACK ADJUSTER

SUPPLY

CONTROL

R-12P

VALVE

OPERATION

CHARGING

When the air brake system is charging, the relay pis ton’s
exhaust seat is against the inlet/exhaust valve due to
the force of the reserve spring. Reservoir air enters the
Bendix

®

R-12P

valve supply port and becomes active

upon the inlet/exhaust valve. At the same time, reservoir
air passes through the R-12P

valve body channel to the

load piston. Supply air builds simultaneously and equally
underneath the inlet/exhaust valve and above the load
piston. While supply pressure continues to hold the inlet/

TRAILER BRAKE SYSTEM WITH R-12P

PILOT RELAY VALVE

exhaust valve against its seat, it also moves the load piston
into contact with the relay piston. However, even though
force is increasing on the relay piston, it does not move the
inlet/exhaust valve. The effective area of the inlet/exhaust
valve is larger than the effec tive area of the load piston.
Therefore, load piston force cannot overcome inlet/exhaust
valve force. So supply air builds to governor cut-out and the
inlet/exhaust valve remains closed. This is the position of
the R-12P

valve in normal run mode, as shown in Figure 3.

-- -- -- -- -- ADDITIONAL PLUMBING FOR TOWING TRAILER