Bendix Commercial Vehicle Systems R-12P PILOT RELAY VALVE 4/11 User Manual

Page 4

Advertising
background image

4

FIGURE 6 - RAPID EXHAUST

FIGURE 7 - EQUALIZING (SLOW) APPLICATION

FIGURE 8 - EQUALIZING (SLOW) EXHAUST

LOAD PISTON

INLET/EXHAUST

VALVE

CONTROL PORT

DELIVERY PORT

SUPPLY PORT

RELAY PISTON

EXHAUST

LOAD PISTON

INLET/EXHAUST

VALVE

CONTROL PORT

DELIVERY PORT

SUPPLY PORT

RELAY PISTON

LOAD PISTON

INLET/EXHAUST

VALVE

CONTROL PORT

DELIVERY PORT

SUPPLY PORT

RELAY PISTON

RAPID EXHAUST

Figure 6 shows a rapid service brake release. Air above
the relay piston travels back out the control port to be
exhausted. With the lack of air pressure above the
piston, air pressure below lifts the piston, closing the inlet
and opening the exhaust. Delivery air then exhausts to
atmosphere.

EQUALIZING (SLOW) APPLICATION

When a control signal enters the Bendix

®

R-12P

valve,

it acts on the relay piston. However, Figure 7 shows the
control signal passing through the valve without causing
piston movement. The air is passing through the relay
piston’s equalizing orifi ce, directly through the valve and
out the delivery port to the next valve in the air system.
This situation occurs if air pressure build-up is slow and
the pressure above the relay piston is not strong enough
to open the valve. (Air pressure above the piston must be
at least 3 psi greater than air pressure below the piston to
cause movement.)

In the equalizing application, even though the inlet valve
does not open, the control signal is not decreased because
the equalizing orifi ce allows it to pass directly through the
R-12P

valve. Note that this condition exists during very

slow service brake applications.

For example, if a vehicle is traveling over a long downhill
grade, the driver may want to limit speed and maintain
vehicle control through proper gearing, engine speed and
a light service brake application.

If, during the light brake application, the driver modulates
the treadle slowly, and not enough to open the R-12P

inlet

valve, the desired control pressure will still pass on to the
next valve, maintaining zero differential.

Advertising