Assembly – Bendix Commercial Vehicle Systems ET-S SUSPENDED ELECTRON TREADLE6/04 User Manual

Page 4

Advertising
background image

4

FIGURE 6 - ELECTRICAL TEST SCHEMATIC FOR THE DETROIT DIESEL CONNECTOR

FIGURE 7 - ELECTRICAL TEST SCHEMATIC FOR THE CATERPILLAR CONNECTOR

POWER

SUPPLY

(9-16 VDC)

300,000 OHM RESISTOR

TEST LOAD

DIGITAL

VOLT/

OHM

METER

PIN C

GROUND

PIN B

VOUT

(OUTPUT)

PIN A
VREF

(INPUT)

POTENTIOMETER

PC. NO. ON THIS SURFACE

POTENTIOMETER

Closed Throttle (open) Range: 7-18%

Open Throttle (full) Range: 74-84%

PEDAL

POSITION

SENSOR

(PWM)

.001µF

(CABLE)

POSITION SENSOR

47,000 OHM ±5%

RESISTOR

PIN C

GROUND

2000 OHM ±5%

RESISTOR

PIN A VREF

(INPUT)

PIN B

VOUT

(OUTPUT)

Closed Throttle (open) Range: 10-20%

Open Throttle (full) Range: 75-90%

Caterpillar output voltage is Pulse Width Modulated

3. Inspect the cable assembly for loose or frayed wires,

physical damage, or any contaminants on the connec-
tors. Replace as necessary.

ASSEMBLY

1. Securely clamp the treadle mounting plate.

2. (a) For Detroit Diesel Potentiometers: Align the drive

slot, and engage the potentiometer the drive tang at the
end of the drive shaft (see Figure 4). Rotate the

potentiometer clockwise until the first set of mounting
holes align. Secure using two screws: torque to 25 (±5)
in. lbs.

(b) For Caterpillar Position Sensor: Aligning the drive
slot, the position sensor engages the drive tang at the
end of the drive shaft (see Figure 4). Rotate the position
sensor clockwise until the first set of mounting holes
align. Secure using two screws : torque to 20 (±2) in.
lbs.

Advertising