SECTION VI A - TESTING THE MODULATOR

F E D

C B A

1
2
3

K J H G F

E D C B A

H1

LEFT FRONT MOD. COMMON

F1

LEFT FRONT MOD. EXHAUST

G1

LEFT FRONT MOD. HOLD

C1

RIGHT FRONT MOD. COMMON

E1

RIGHT FRONT MOD. EXHAUST

D1

RIGHT FRONT MOD. HOLD

F1

LEFT REAR MOD. COMMON

D1

LEFT REAR MOD. EXHAUST

E1

LEFT REAR MOD. HOLD

A1

RIGHT REAR MOD. COMMON

C1

RIGHT REAR MOD. EXHAUST

B1

RIGHT REAR MOD. HOLD

1
2
3

18 PIN CONNECTOR

30 PIN CONNECTOR

TURN IGNITION OFF. REFER TO

ILLUSTRATION, DISCONNECT WIRE

HARNESS CONNECTOR FROM

EC-17

CONTROLLER.

START HERE

PROBE CONNECTOR WITH VOLT/OHM METER AND NOTE

THAT PROPER RESISTANCE VALUES ARE OBTAINED FOR

MODULATOR BEING TESTED.

RESISTANCE VALUES FOR BENDIX

®

M-21

AND

M-22

MODULATORS.

HOLD TO COMMON:

READ 3.5 TO 5 OHMS

EXHAUST TO COMMON:

READ 3.5 TO 5 OHMS

EXHAUST TO HOLD:

READ 7 TO 10 OHMS

FOR BENDIX

®

M-32

MODULATORS.

HOLD TO COMMON:

READ 4.9 TO 7 OHMS

EXHAUST TO COMMON:

READ 4.9 TO 7 OHMS

EXHAUST TO HOLD:

READ 9.8 TO 14 OHMS

PROBE CONNECTOR PINS WITH A MEGOHMMETER AND

VERIFY THAT NO CONTINUITY EXISTS.

COMMON TO GROUND:

NO CONTINUITY

HOLD TO GROUND

NO CONTINUITY

EXHAUST TO GROUND

NO CONTINUITY

INSPECT CONNECTOR AND RECONNECT

TO EC-17

CONTROLLER. TURN IGNITION

ON AND PASS MAGNET OVER RESET ON

EC-17

CONTROLLER. NOTE REACTION

OF RED LEDs.

SAME RED LEDs

ILLUMINATED?

REPEAT “INITIAL START-UP

PROCEDURE.” IF THIS TEST STEP

HAS REPEATED TWICE - REPLACE

THE EC-17

CONTROLLER.

NO

YES

YES

NO

GO TO SECTION VI B AND

CONTINUE TESTING

NO

YES

REPLACE THE EC-17

CONTROLLER.

GO TO SECTION IV

“INSPECTION FOR

ILLUMINATED LEDs”

AND RETEST.

ARE RESISTANCE

VALUES CORRECT?

ARE ANY RED LEDs

ILLUMINATED?