SECTION VI B - TESTING THE MODULATOR

GO TO MODULATOR, INSPECT WIRING CONNECTOR.

DISCONNECT CONNECTOR AND TEST RESISTANCE

BETWEEN PINS ON MODULATOR.

RESISTANCE VALUES FOR BENDIX

®

M-21

AND M-22

MODULATORS.

HOLD TO COMMON:

READ 3.5 TO 5 OHMS

EXHAUST TO COMMON:

READ 3.5 TO 5 OHMS

EXHAUST TO HOLD:

READ 7 TO 10 OHMS

RESISTANCE VALUES FOR BENDIX

®

M-32

MODULATORS.

HOLD TO COMMON:

READ 4.9 TO 7 OHMS

EXHAUST TO COMMON:

READ 4.9 TO 7 OHMS

EXHAUST TO HOLD:

READ 9.8 TO 14 OHMS

TEST EACH PIN TO VEHICLE GROUND WITH A MEG-

OHMMETER AND NOTE THAT NO CONTINUITY EXISTS.

EXHAUST COMMON HOLD

A

B

C

CONNECTOR ON M-21

OR M-22

MODULATOR.

START HERE FROM

SECTION VI A

REPLACE THE MODULATOR.

YES

REPEAT THE “INITIAL

START-UP PROCEDURE”

REPAIR OR REPLACE MODU-

LATOR WIRE HARNESS.

GO TO SECTION IV “INSPECTION FOR

ILLUMINATED LEDs” AND RETEST.

NO

YES

YES

NO

NO

RECONNECT CONNECTOR TO MODULATOR.

TURN IGNITION ON AND PASS MAGNET OVER

RESET ON EC-17

CONTROLLER. NOTE

REACTION OF RED LEDs.

RESISTANCE READINGS

CORRECT?

ARE ANY RED LEDs

ILLUMINATED?

SAME RED LEDs
ILLUMINATED?