Bendix Commercial Vehicle Systems DRM DRYER RESERVOIR MODULE 3/07 User Manual

Bendix, Dryer reservoir module with ad-is, Description

Advertising
background image

1

Air

Connection

Function/Connection

No.

Port ID

DESCRIPTION

The function of the dryer reservoir module (DRM

) is to

provide heavy vehicles with an integrated vehicle air dryer,
secondary reservoir, purge reservoir, governor and a number
of the charging valve components in a module. The DRM

dryer module model covered in this Service Data Sheet is
the first to be released, see updates to this Service Data
Sheet for other models.

The DRM

dryer module includes an integrated solution air

dryer (AD-IS

®

), a reservoir (including a separate purge

reservoir section) a governor and four pressure protection
valves. These have been designed as an integrated air supply
system.

The function of the AD-IS

®

air dryer is to collect and remove

air system contaminants in solid, liquid and vapor form
before they enter the brake system. It provides clean, dry
air to the components of the brake system which increases
the life of the system and reduces maintenance costs. Daily
manual draining of the reservoirs is eliminated.

The function of the pressure protection valves is to both
control the order in which the components receive air from
the AD-IS

®

air dryer, and also to protect each reservoir from

a pressure loss in the other reservoir or a pressure loss in
an air accessory.

FIGURE 1 - DRYER RESERVOIR MODULE

The air dryer consists of a “spin on” desiccant cartridge
secured to a base assembly.

The base assembly contains a delivery check valve
assembly, safety valve, heater and thermostat assembly,
pressure protection valves, threaded air connections and
the purge valve assembly.

Bendix

®

Dryer Reservoir Module with AD-IS

®

Air Dryer

SD-98-9808

1

IN

21

PRI

22

AUX 1

23

AUX 2

UNL

Unloader Control Air (D-2A

Governor)

2

RES

Common Reservoir Pressure (D-2A

Governor)

2

EXH

Governor Exhaust

1

TABLE 1 - DRM

DRYER MODULE AIR CONNECTIONS

Inlet Port (air in).

1

Delivery Port out (to Primary reservoir)

1

Auxiliary Delivery Port (air out).

4

Auxiliary Delivery Port (air out).

1

DESICCANT

CARTRIDGE

SECONDARY

RESERVOIR

AD-IS

®

Air Dryer

INTEGRATED

PURGE RESERVOIR

GOVERNOR

PRESSURE PROTECTION

VALVES (4)

AUXILIARY

DELIVERY PORTS

(5)

HEATER/

THERMOSTAT

SAFETY VALVE

AD-IS

®

AIR DRYER PART NUMBER STAMPED HERE

MOUNTING

BOLTS (3)

Advertising