Ad-is, Air dryer troubleshooting chart (continued) – Bendix Commercial Vehicle Systems DRM DRYER RESERVOIR MODULE 3/07 User Manual

Page 12

Advertising
background image

12

DRM

/AD-IS

®

AIR DRYER TROUBLESHOOTING CHART (Continued)

SYMPTOMS

CAUSE

REMEDY

C. Refer to Symptom 1, Remedy B.

D. Repair or replace purge valve assembly.

E. Check governor at both “cut-in” and “cut-out”

position for (i) proper pressures and (ii)
excessive leakage at fittings and exhaust.

F. Repair or replace purge valve assembly.

C. Defective AD-IS

®

air

dryer delivery check
valve.

D. Leaking Turbo Cutoff

valve.

E. Defective governor.

F. Leaking purge valve

control piston quad-ring.

B. System pressure too

high (>135 p.s.i.)

C. Excessive pressure

pulsations from
compressor. (Typical
single cylinder type).

D. Safety valve setting too

low (<150 p.s.i.)

A. Test to determine if air is passing through check

valve. Repair or replace. Refer to Symptom 1,
Remedy B.

B. Test with accurate gauge. Replace governor if

necessary.

C. Increase volume in discharge line. This can be

accomplished by adding a 90 cubic inch (or
larger) reservoir between the compressor and the
AD-IS

®

air dryer.

D. Replace safety valve.

3. Safety valve on air dryer

“popping off” or
exhausting air.

A. Defective AD-IS

®

air

dryer delivery check
valve.

4. Constant exhaust of air

at air dryer purge valve
exhaust or unable to
build system pressure.
(Charge mode.)

A. With compressor loaded, apply soap solution

on purge valve exhaust, to test for excessive
leakage. Repair or replace purge valve as
necessary.

B. Refer to paragraph 5 of Operation and Leakage

Tests for heater and thermostat test.

A. Air dryer purge valve

leaking excessively.

B. Purge valve frozen open

- faulty heater and
thermostat, wiring,
blown fuse.

Advertising