Bendix, Ad-9si, Air dryer troubleshooting chart – Bendix Commercial Vehicle Systems AD-9si Oil Coalescing Air Dryer User Manual

Page 15

Advertising
background image

15

BENDIX

®

AD-9si

AIR DRYER

TROUBLESHOOTING CHART

SYMPTOM

CAUSE

REMEDY

5. Cannot build system air

pressure.

A. Supply pressure to the air dryer is not

sufficient.

A. Ensure the supply pressure to the air dryer is greater than

110 psi during the system charge.

B. Kinked or blocked (plugged) discharge

line.

B. Check to determine if air passes through discharge line.

Check for kinks, bends, excessive carbon deposits, or ice

blockage.

C. Excessive bends in discharge line

(water collects and freezes).

C. Discharge line should be constantly sloping from compressor

to air dryer with as few bends as possible.

D. Refer to Symptom 4.

D. Refer to Symptom 4, Remedy A.

E. Refer to Symptom 7.

E. Refer to Symptom 7, Remedies A and B.

6. Air dryer does not purge or

exhaust air.

A. Faulty air dryer purge valve.

A. After determining that air reaches the purge valve piston by

installing a Tee fitting with a pressure gauge into the control

port, repair purge valve if necessary.

B. See Causes B, E, and F for Symptom

#4.

B. Refer to Symptom 4, Remedies B, E, and F.

7. Desiccant material being

expelled from air dryer purge

valve exhaust (may look like

whitish liquid or paste or

small beads.)

A. Faulty dryer cartridge.

A. Replace the Bendix

®

AD-9si

air dryer cartridge or AD-9si air

dryer.

B. Excessive dryer vibration.

B. Check the AD-9si air dryer mounting for looseness or

damage. Repair mounting and replace cartridge.

8. Unsatisfactory desiccant life. A. Excessive system leakage.

A. Refer to Symptom 1, Remedy A.

B. Wrong vehicle application for AD-9si

air dryer.

B. Refer to Symptom 2, Remedy C.

C. Compressor passing excessive oil. C. Check for proper compressor installation; if symptoms

persist, replace compressor. Refer to

Bendix

®

Advanced

Troubleshooting Guide for Air Brake Compressor

(BW1971).

9. “Pinging” noise excessive

during compressor loaded

cycle.

A. Single cylinder compressor with high

pulse cycles.

A. A slight “pinging” sound may be heard during system build-

up when a single cylinder compressor is used. If this sound

is deemed objectionable, it can be reduced substantially by

increasing the discharge line volume.

This can be accomplished by adding a 90 cubic inch (or

larger) reservoir between the compressor and the AD-9si

air

dryer.

10. The air dryer purge piston

cycles rapidly in the

compressor unloaded (non-

compressing) mode.

A. Compressor fails to “unload”.

A. Check the air hose from the AD-9si air dryer control port to the

compressor for a missing, kinked, or restricted line. Install or

repair the air hose. Repair or replace the compressor unloader.

Advertising