7

COMPRESSOR

DESICCANT

BED

DELIVERY

CHECK

VALVE

PURGE

VALVE

TURBO

CUT-OFF

VALVE

(CLOSED)

CONTROL

PORT

SUPPLY

PORT

FRONT

RESERVOIR

SAFETY

VALVE

REAR

RESERVOIR

PURGE

ORIFICE

OIL

COALESCING

FILTER

CONTROL

LINE

PURGE AIR

EXTENDED

PURGE

PORT

EXHAUST

DELIVERY

PORT

FIGURE 5 -

BENDIX

®

AD-9si

AIR DRYER WITHOUT GOVERNOR—PURGE CYCLE

TURBO CUT-OFF FEATURE

(Refer to Figures 3

and 5)
The primary function of the turbo cut-off valve is to prevent

loss of engine turbocharger air pressure through the

Bendix

®

AD-9si

air dryer when the dryer is in the purge

mode.
At the onset of the purge cycle, the downward travel of the

purge piston is stopped when the turbo cut-off valve (the

tapered portion of the purge piston) contacts its mating

metal seat in the purge valve housing. With the turbo cut-off

valve seated (in the closed position), air in the compressor

discharge line — as well as the AD-9si air dryer inlet port

— cannot enter the air dryer. By completing these actions,

the turbo cut-off effectively maintains turbocharger boost

pressure to the engine.