Compressor Installation and Application Review

Section IV

Air System Components (cont’d)


Compressor Air Induction System - Naturally Aspirated Compressor Applications Only
(Cont’d)

Line

size

_____________________________________


Line

length

___________________________________


Expected/Measured

Worst-Case Inlet Air Temperature: _______________


Was measured restriction less than 25 in H

2

O? YES

NO


Is the inlet air temperature greater than 170°F? YES

NO

Recommended Test Procedure:
Install a temperature probe in the air compressor inlet hose or fitting as close to the
compressor as possible. Operate the vehicle such that the engine is at operating
temperature and the compressor is loaded/pumping. Record the compressor air inlet
temperature and note the ambient temperature. To obtain the maximum air inlet
temperature, add the difference between the recorded inlet temperature and the noted
ambient temperature to the maximum expected ambient temperature.


Was the restriction measured per the recommended procedure? YES

NO


If no, describe the procedure used: ___________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________