8

NON-DUCTED INSTALLATION ONLY:

From parts bag: Attach

Non-Duct Diverter to Air Box

with 2

Screws and 2 Washers.

11

NON-DUCTED INSTALLATION ONLY:

Purchase a set of (2) non-ducted filters for 30” wide hoods

(Model BPPF30) & 36” wide hoods (Model BPPF36) or

a set of (3) non-ducted filters for 42” wide hoods (Model

BPPF42) from your local distributor or retailer. Attach the

non-ducted filters to the aluminum mesh filters following

instructions packed with the non-ducted filters.

FOR NON-DUCTED INSTALLATIONS - Skip to “INSTALL

THE HOOD”.

9

NON-DUCTED INSTALLATION ONLY:

Remove 2

Screws holding Non-Duct Plate to Non-Duct

Plenum and remove plate.

10

NON-DUCTED INSTALLATION ONLY:

Insert short end of

Non-Duct Plate into Non-Duct

Plenum

Slot. Attach with 2 Screws removed in Step 9.

SCREWS

SCREWS

NON-DUCT

PLATE

NON-DUCT

PLENUM

NON-DUCT

PLATE

ç

SLOT

7

Remove 2

Screws holding Damper / Duct Connector

to hood. Remove damper/duct connector from inside the

hood.

FOR DUCTED INSTALLATIONS - Skip to Step 12.

DAMPER /

DUCT CONNECTOR

6

Remove 6

Screws holding Bottom Pan to hood. Set bot-

tom pan and screws aside.

PREPARE THE HOOD

5

Remove the

Aluminum Filters

from the hood.

4

Remove all

protective polyfilm

from the hood

(stainless steel

hoods only).

3

Remove parts bag

from inside the

foam packaging

end cap.

ALUMINUM

FILTERS

ç

(1)

PULL

DOWN

(2)

LIFT

OUT

ç

NON-DUCT

PLATE

NON-DUCT

DIVERTER

Advertising