Install the hood, Warning – Broan EVOLUTION QP236WW User Manual

Page 5

Advertising
background image

MODELS QP230BC • QP230BL • QP230SS • QP230WW

QP236BC • QP236BL • QP236SS • QP236WW

QP242BC • QP242BL • QP242SS • QP242WW

Page 5

12

DUCTED INSTALLATION ONLY:

Remove 3¼” x 10 vertical, 3¼” x 10” horizontal, or 7-inch

round

knockout plate(s) as appropriate for your ducting

method.

3¼” X 10”

HORIZONTAL

KNOCKOUT

PLATE

3¼” X 10”

VERTICAL

KNOCKOUT

PLATE

7” ROUND

KNOCKOUT

PLATE (also

remove 3¼” x 10”

vertical plate)

7” ROUND

DUCT

PLATE

INSTALL THE HOOD

15

Run

House Power Cable between service panel and hood

location. Attach power cable to hood using appropriate clamp.

16

Hang hood from (4) mounting screws driven part-way into

cabinet locations (shown in illustrations under “PREPARE

HOOD LOCATION”). Mounting screws are included in parts

bag. Slide hood back towards wall until mounting screw

heads are engaged in narrow end of keyhole slots in top of

hood. Tighten screws securely. Add 5th mounting screw in

center hole in hood and tighten securely.

17

DUCTED INSTALLATION ONLY:

Connect ductwork to hood and use duct tape to make joints

secure and air-tight.

Make sure the damper / duct connector

enters the ductwork and that the damper opens and closes

freely.

HOUSE

POWER CABLE

WARNING

To reduce the risk of electrical shock, switch power off

at service panel. Lock or tag service panel to prevent

power from being switched on accidentally.

ELECTRICAL

WIRING BOX

COVER

14

Remove

Electrical Wiring Box Cover from inside

of hood and appropriate

Electrical Power Cable

Knockout from top or back of hood.

ELECTRICAL

POWER

CABLE

KNOCKOUT

13

DUCTED INSTALLATION ONLY:

Attach

3¼” x 10” Damper/Duct Connector (if using 3¼”

x 10” duct) or

7” Round Duct Plate (if using 7-inch round

duct) over the knockout opening.

Notes:
To accomodate off-center ductwork, the 3¼” x 10”

damper/duct connector can be installed up to ½” on either

side of the hood center and the 7” round duct plate can

be installed up to ½” on either side of the hood center.
Install the 3¼” x 10” Damper/Duct Connector with the

Damper Flap Pivot nearest the Top/Back Edge of

Hood.

TOP/BACK

EDGE OF

HOOD

DAMPER

FLAP

PIVOT

3¼” X 10”

DAMPER /

DUCT

CONNECTOR

Advertising