Table 1-5 Troubleshooting

PROBLEM

CAUSE

AREAS TO CHECK / CORRECTION

Active LED does
not Illuminate

No Line Power

Check power source, restore

Defective line cord.

Fuses Opened

Check fuses, replace if needed. See
“Fuse Drawer/Fuse Replacement” on
page 19.

Defective monitor
circuitry.

Return Wattcher, line section, and
elements to the factory. See “Customer
Service” on page 16.

Line voltage selector
switch in wrong
position.

Set switch to proper operating voltage.

No meter indication

No RF power

Check RF source.

Arrow on plug-in
element pointing in
wrong direction

Change position of element.

No pickup from DC
wiper contact

Adjust wiper contact. See “Adjusting the
Element Wiper Contact” on page 18.

Open or short circuit
in DC meter cable

Replace defective DC meter cable.

Open or short circuit
in line section circuit
in cable.

Replace defective cable.

Meter burned out or
damaged

Replace defective meter. See “Meter
Replacement” on page 21.

Defective monitor
circuitry.

Return Wattcher, line section, and
elements to the factory. See “Customer
Service” on page 16.

Intermittent or
inconsistent meter
readings

Faulty transmission
line

Inspect line connectors. Replace
defective connector.

Dirty DC contact on
elements

Clean DC contacts. See “Cleaning” on
page 15.

Sticky or defective
meter

Replace defective meter. See “Meter
Replacement” on page 21.