Specifications, General – Bird Technologies ACMI User Manual

Page 43

Advertising
background image

31

Specifications

General

Directivity, Min.

108 – 960 MHz
960 – 2400 MHz


30 dB
26 dB

VSWR Alarm Setpoint

1.3:1.0 to 2.5:1.0 by 0.1:1.0 steps.
Refer to "Power/Alarm Connector"
on page

7 for information about

power limitations.

Alarm Relays

Dry, form C. Common, normally
open, & normally closed contacts.

Relay Contact Rating

100 VDC @ 0.5 A

Visual Alarm

Red LED will light to indicate
an alarm

Alarm Stimulus

VSWR setpoint exceeded,

response time proportional to

overload

Alarm Reset

Local mechanical reset switch

Remote input (Reset if VDC =

0 to +0.8 V)

RF Connectors

Male or Female, N or 7/16 DIN

Monitor Port Connectors

Female N, TNC, or BNC

Monitor Port Coupling

–63 dB nominal

Passive Intermodulation
Products


< –130 dBc

Ethernet Port

Connector
Protocol


RJ-45
10/100 IEEE802.3

Power/Alarm Parallel Port

Female DB-15 connector

Power Requirements

ACMI-x-xxxxxL

ACMI500-x-xxxxxL

ACMI-x-xxxxxM

ACMI500-x-xxxxxM

ACMI-x-xxxxxH

ACMI500-x-xxxxxH

+/- (8 to 18) VDC @ 2.65 W

+/- (8 to 18) VDC @ 2.65 W

+/- (18 to 36) VDC @ 2.65 W

+/- (18 to 36) VDC @ 2.65 W

+/- (36 to 72) VDC @ 2.65 W

+/- (36 to 72) VDC @ 2.65 W

Analog Outputs

0 to 5 V full scale, 200 ohm
output impedance

Temperature

Operating
Storage


0 to 50 °C (32 to 122 °F)
–20 to +80 °C (–4 to +176 °F)

Altitude, Max.

3000 m (10,000 ft.)

Humidity, Max.

95% non-condensing

Dimensions, Nominal,
without connectors

4.75” L x 6.44” W x 1.22” H
(121 x 164 x 31 mm)

Weight, Max.

2 lbs. (0.9 kg)

Advertising