Electric Heater

WARNING

Before performing any service that involves electrical

connection or disconnection and/or exposure to

electrical components, always perform the Electrical

LOCKOUT/TAGOUT Procedure. Disconnect all circuits.

Failure to comply with this procedure can cause

property damage, injury or death.

Electrically heated machines are available in 208, 240,

or 440-480 volts, single- or three-phase only. They are

prewired at the factory and only one common connection

is required. Use L1 and L2 for single-phase units and L1,

L2 and L3 for three-phase units.

Additional instructions are located inside the control

box. Make sure the wire size is adequate to carry the

amperage load.

The temperature is controlled by the thermostat located

in the control box.

Thermostat –

Turn screw clockwise to

increase temperature;

Turn counterclockwise to

decrease temperature

Incoming

power

connection

Thermostat & Power Connection Locations

Gas Heater

Before making a gas connection, verify the gas type. A tag

is attached to the gas valve that will indicate the correct

gas type (L.P. or Natural) to be supplied to the unit.

Note: If the tag is missing, the gas type can be determined

by inspecting the gas valve. A Natural gas valve will

have a pressure regulator where a L.P. gas valve will

not.

WARNING

Instructions to be followed in the event the operator

smells gas or otherwise detects a gas leak must be

posted in a prominent location. This information

can be obtained from the local gas company or gas

supplier.

WARNING

All connections must be sealed with a joint compound

suitable for the gas being used and all connections

must be tested with a solution of soapy water before

lighting any pilots.

Never use matches, candles, or any other ignition

source to check for leaks. If gas odors are detected,

shut off the gas supply to the appliance at the main

shutoff valve and immediately contact the local gas

company or an authorized service agency for service.

The natural gas valve has a pressure regulator

for minor adjustments to the gas pressure. L.P.

gas pressure must be adjusted by the customer’s

regulator.