Setup, Page 7, Figure 2: the rear connections – Blizzard Lighting RGBAW ToughStick (Rev C) User Manual

Page 7

Advertising
background image

Page 7

ToughSTICK™ RGBAW Manual - Rev. C

Copyright (c) 2012 Blizzard Lighting, LLC

Figure 2: The Rear Connections

AC Power In

3-Pin

DMX512 In

AC Power Out

3-Pin

DMX512 Out

Extended, waterproof AC power and 3-pin DMX connections.

3. SETUP

Fuse Replacement

CAUTION! The ToughSTICK™ RGBAW utilizes a high-output switch-mode power supply

with an internal fuse. Under normal operating conditions, the fuse should not require

replacement. The fuse is field replaceable, however it is an advanced procedure suited to

qualified individuals. Should your ToughSTICK™ fuse require replacement, please contact

Blizzard Lighting for instructions, or to return your unit for service.

Connecting A Bunch of ToughSTICK™ RGBAW Fixtures

You will need a serial data link to run light shows using a DMX-512 controller or to run

shows on two or more fixtures set to sync in master/slave operating mode. The combined

number of channels required by all the fixtures on a serial data link determines the number

of fixtures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line. Also, connecting

more than 32 fixtures on one serial data link without the use of a DMX optically-isolated

splitter may result in deterioration of the digital DMX signal. The maximum recommended

cable-run distance is 500 meters (1640 ft). The maximum recommended number of

fixtures on a serial data link is 32 fixtures.

Data/DMX Cabling

To link fixtures together you’ll need data cables. You should use data-grade cables that can

carry a high quality signal and are less prone to electromagnetic interference.

For instance, Belden© 9841 meets the specifications for EIA RS-485 applications. Standard

microphone cables will “probably” be OK, but note that they cannot transmit DMX

data as reliably over long distances. In any event, the cable should have the following

characteristics:

2-conductor twisted pair plus a shield

Maximum capacitance between conductors – 30 pF/ft.

Maximum capacitance between conductor & shield – 55 pF/ft.

Maximum resistance of 20 ohms / 1000 ft.

Nominal impedance 100 – 140 ohms

Advertising