BLUESHAPE CVS8X User Manual

Page 12

Advertising
background image

12

Battery LED indications

#

OPERATING MODE

TIMEOUT

LED INDICATION

1

BATTERY DETECTION
Battery detected while the other on
the same pair is already charging

BATTERY WAITING:
GREEN: 1sec ON/1sec OFF

2 BATTERY NOT ALLOWED

10Kohm < ID resistor < 60Kohm

BATTERY NOT ALLOWED:
GREEN: 500ms/RED: 500ms

3

BATTERY EVALUATION

i) Total pack voltage < 8000mV

ii) I < 10mA

If the charging does not rise within
30sec, the battery does not accept
charge

iii) Single cell voltages < 2800mV

10mA < I < 50mA

iv) Single cell voltages > 2800mV

Total pack voltage < 13000mV
50mA < I < 300mA

3600sec

1200sec

VOLTAGE TOO LOW:
RED flashing
500ms ON/500ms OFF

BATTERY FAILURE:
Steady RED

PRECHARGE-1:
ORANGE flashing
500ms ON/500ms OFF

PRECHARGE-2:
ORANGE flashing
250ms ON/250ms OFF

4 CONSTANT CURRENT MODE

13000mV < V < 16750, I = max 4.9A

18000sec CC-MODE:

Steady ORANGE

5

CONSTANT VOLTAGE MODE
V >16750mV
150mA < I < 4900mA

10800sec

CV-MODE:
ORANGE 500ms/
GREEN 500ms

6

FULL CHARGE
V

≅ 16800mV

I

≅ 150mA

FULL CHARGE:
Steady GREEN

7

OTHER INDICATIONS
In the case of premature charge
termination, the charger retries to
charge the battery every 30 seconds.

If after 10 minutes, there is still no
response, the indication is changed
into ‘BATTERY FAILURE’

PREMATURE CHARGE
TERMINATION:
RED: 250ms ON/100ms OFF
/250ms ON /1sec OFF
(2 blinks + 1 pause)

BATTERY FAILURE:
Steady RED