BLUESHAPE CVS8X User Manual

Page 14

Advertising
background image

14

Technical specifications

Type

Constant current and voltage control system with timer
interventions

CC-MODE: Output current

4900mA ± 1%

CC-MODE: Vmax

16800 ± 50mV (0.3%)

CV-MODE: Vmax

16800 ± 50mV (0.3%)

CV-MODE: Cutoff current

150mA ± 10mA

Short circuit protection

Available

Overcharge protection

Available

Overtemperature protection

Available

LEDS

3 colour type for BAT1, BAT2, BAT3, BAT4 and AUX

LCD

20x4 Blue/White backlight

Special features

IPCS and CTP

Auxiliary power

13.8V 110W (max)

Power supply

AC mains 100V - 240V ~, 47 - 63 Hz autoselect

Fuse

1 x 220V 2.5A (5x20mm quick blow) + 1 spare

Power consumption

100W max / 90W typical

Operating temperature range

0°C - 45°C

Storage temperature range

-20°C - 65°C (-4°F - 149°F)

Dimensions

170 x 150 x 280 mm

Weight

2900g

The CE certification is pending.