BLUESHAPE MVQUICK Hot-Swap adapter User Manual

Page 3

Advertising
background image

3

Principle of operation

MVQUICK features an internal battery system of about 21Wh. This
power source is automatically connected to the output terminals
(becoming the only power source) whenever the main V-Lock
battery is not installed, removed or empty (voltage below 12V).

Alternatively, when a V-Lock battery with a voltage greater than 12V
is installed, it becomes the main power source connected to the
output connector.

If, during usage, the V-lock battery voltage drops below 12V, or it is
removed, MVQUICK automatically provides a continuous power
supply to the device without any power interruption.
As soon as this switchover takes place and MVQUICK operates
through its internal power source, the 3 LEDs become alighted
(depending on the state of charge) to alarm the user that the main
power source, coming from the external V-Lock battery is no more
available and the internal UPS is providing continuity power.

When operating as the main power source, the runtime provided by
MVQUICK depends by the state of charge of its internal battery and
the actual power consumption.

The LED array displays the state of charge based on the internal
battery voltage and the following criteria:

Voltage

Approx. state of charge

LEDs

> 15.2V

100% ~ 66%

All 3 LEDs on [H M L]

15.2V ~ 14.4V

66% ~ 33%

2 LEDs on [M L]

14.4V ~ 13.0V

33% ~ 10%

1 LED on [L]

< 13.0V

0% ~ 10%

1 LED flashing [L]