Always turn off water supply at source. It is strongly advised you consult a qualifi ed professional plumber when
attempting to install BREW EXPRESS™ in-the-wall COFFEE SYSTEM.

It is important to make sure there are no confl icts or obstructions in the wall cavity such as plumbing or
electrical wires. If in doubt Contact a qualifi ed professional. DO NOT ATTEMPT INSTALLATION.

IMPORTANT:
It is required that a water fi lter and shut off valve be
installed at source under sink or refrigerator area

A. EXISTING HOME

Determine closest location on wall where BREW EXPRESS™

is to be installed where water can be plumbed by teeing off

water line from sink, refrigerator, ice maker or by simply using

the alternate water jug (not supplied). Drill a hole (7/16” dia)

at the lowest point in the cabinets and route water line through

hole behind cabinets and up wall cavity to the cut opening in

wall. Leave approximately 18” of excess water line at wall

opening for rough-in-box installation. Continue water line to

source. Splicing/coupling is not recommended. A continuous

line will be best to ensure no leaks.

B. NEW HOME CONSTRUCTION

Determine closest location on wall where BREW EXPRESS™

is to be installed where water line can be plumbed by teeing off

water line from source sink, refrigerator or ice maker. Route

water line through studs and up wall cavity to area where wall

opening will be cut prior to sheet rock installation. Allow an

additional length of 18” at area where wall opening will be cut.

Using template provided mark the area to be cut AFTER sheet

rock is installed.

IMPORTANT:
If installing Unit PRIOR to cabinets, it is strongly advised to
consult with cabinet maker and building contractor for exact
height of counter top due to the various thicknesses of
counter tops (tile laminate, granite, etc). For best results
cut hole and install unit AFTER cabinets are installed.

Always turn off power supply at main electrical panel before attempting any electrical installation. Local electrical
codes vary. All electrical installation must be done in accordance with local codes. Installation must be peformed
by a Qualifi ed Electrican only, or equivalent.

IMPORTANT:
Wire the BREW EXPRESS to a GFCI protected circuit. Installation must be peformed by a Qualifi ed Electrican only,
or equivalent.

The BREW EXPRESS

can be installed in most places where power and water are supplied.

See diagrams below for the application best suited for your needs.

OPTION A. (New Construction)

Power can be brought to rough-in-box by
adding a new line from from main breaker panel.
Contact a qualifi ed electrician for this application.
Wire unit to a GFI/GFCI circuit breaker.
NOTE: When routing electrical power to desired
location it is recommended that you allow an additional
18” length of wire at the rough-in-box location.

OPTION B. (New or Existing Construction)

Power to rough-in-box can be tapped from an
existing adjacent electrical outlet. Unit must be wired to
a GFI/GFCI protected circuit.
NOTE: When routing electrical power to desired location it is
recommended that you allow an additional 18” length of wire
at the rough-in-box location.

OPTION C. (Existing Construction)

Electrical outlet can be removed and replaced with the
rough-in-box. Unit must be wired to a GFI/GFCI protected circuit.
NOTE: When routing electrical power to desired location it is
recommended that you allow an additional 18” length of wire
at the rough-in-box location.

6

7

WATER INSTALLATION

POWER INSTALLATION

Shut off valve

Water

Filter

OPTION A

OPTION B

OPTION C