Troubleshooting – Brew Express BE-112 OPERATION GUIDE User Manual

Page 9

Advertising
background image

Display is not illuminated

Ensure the power to the rough-in box is turned on (check circuit breaker).

Ensure brewer is fully pressed into the rough-in box.

Ensure the outlet inside the rough-in box is properly wired. Remove the brewer

and check outlet with volt meter. If power is on and no voltage is detected at the

outlet, wiring is incorrect. Turn off power. Remove power panel cover (two screws)

and check wire source connection.

Check wire connection at source.

Water does not flow from spray head

If the BREW EXPRESS™ has not been used for 30 minutes or longer, it will PREHEAT

the water for 30 seconds. You may be waiting for the preheat cycle to end.

Ensure water has been turned on to the BREW EXPRESS™ (check valve at source).

Ensure the carafe or mug is centered under under the brew basket. BREW EXPRESS™

will not start if the detection sensor does not see a carafe or mug. Status light will blink.

The detection sensor may not see a flat black or clear surface. If mug or carafe is flat black
or clear, then switch to a different type of container.

Ensure the water line is properly connected inside the rough-in box. Remove The four

mounting screws on the side and pull out brewer. Check for pinched or kinks in the water

supply line. The quick connector from the brewer must be pressed securely into quick

connector from from water source.

Ensure the water pressure is adequate. The BREW EXPRESS™ will not operate if water

pressure is under 30 PSI. LED display will flash EEEE if water pressure is too low.

Check the water filter (if present) at the supply. If filter is clogged replace filter.

If problem persist and there is no filter in the water line, then coffee system maybe clogged by debris.
Contact dealer or Lance Larkin™ for service. 1(866)268-5953

7

TROUBLESHOOTING

Advertising