A13 14 – Clay Paky ALPHA PROFILE 700 ST (C61366) User Manual

Page 25

Advertising
background image

25

ALPHA PROFILE 700 &

ST

Lower Side

Upper Side

2

Lower Side

A

Upper Side

3

1

A

A

13

14

1

2

12

Lamp change - Fig 13
Take the new lamp out of its package and insert in the fitting.
WARNING: do not touch the lamp’s envelope with bare hands.
Should this happen, clean the bulb with a cloth soaked in alcohol
and dry it with a clean, dry cloth.
IMPORTANT: Make sure the lamp is inserted with the external
contact (A) facing the elliptical reflector’s slot.
CAUTION: fast lamp ON-OFF cycles (for example 10 minutes ON /
10 minutes OFF) will reduce the lamp life.

Lamp regulation - Fig. 14
To centre the lamp, turn the three adjusting screws as shown in the figure.

Opening and closing lamp compartment - Fig. 12

Continue

Advertising
This manual is related to the following products: