54 • Cage and Blade Installation

ClearCube Product Manual and Installation Guide

Power Modules

The R4300 contains two Power Supply Units (PSUs) and a Dual Input Module (DIM). With

the redundancy provided by two PSUs and two power inputs, the R4300 will stay running

even if one PSU fails, or a power input fails, or if a PSU and a power input fail together.

The PSUs are factory-installed, field-replaceable units, and can be hot-swapped by

removing the fan pack to access the unit (see Replacing the R4300 Fan Pack on

page 106). Each PSU has a green LED visible through the fan pack that indicates its

powered-on status. If one of the PSUs fails, the DC POWER status LED on the RMM

turns red to indicate a failure, and the green LED on the failed power supply turns red.

The DIM allows providing redundant power inputs. For best reliability, attach a power

cord to both receptacles, and plug the cords into separate power sources. When using

only one power source, plug it into the receptacle labeled A for best reliability. The

DIM is not hot-swappable. Fuses on the DIM can be accessed by powering down the

Cage and removing the fan module.

Table 9 R4300 Network Module Features

Connectors

ETHERNET

RJ45 connections that provide the 10/100/1000 Ethernet connections for each PC Blade in

the Cage. The numbers correspond to the Blade slot numbers on the front of the Cage.

LED

PRI

Blue

Blue LED that, when lit, indicates that the Status LEDs above the Management Bay module

are displaying status for the Primary Network connections in this module. The Status LEDs

display these conditions:

Green = good network connection

Off = no network connection, or no Blade

CAUTION: DOUBLE POLE/NEUTRAL FUSING

The DIM employs fuses in both the neutral and hot lines. Please contact
ClearCube or a ClearCube-certified technician for assistance with
servicing or replacing these modules or replacing the fuses in them.

Primary NIC

Selected LED