41 and, Generic, Generic wiring — interface module – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 42: Channel edm, manual reset), Generic wiring — interface module (2-channel, Edm, manual reset)

Advertising
background image

Generic Wiring — Interface Module (2-Channel EDM, Manual Reset)

+24V dc

0V dc

S1

S2

Y4

Y2

14

24

34

S3

S4

Y3

Y1

13

23

33

K2

K1

Machine

Control

MPCE

2

MPCE

1

IM-T-9A**

Bn (Pin #1)

+24V dc

0V dc

OSSD 1

OSSD 2

MPCE Monitoring

Reset/
Test

n.c.

N.C.

n.c.

Ground

Gn/Ye (#7)

Bu (#6)

Bk (#5)

Wh (#4)

Vi (#8)

Or (#3)

Or/Bk (#2)

*

*

Receiver

8-pin male Euro-style

face view

*

NOTE:

• Pins 2 and 3 are not connected, or are connected in parallel to the same color wire from the emitter cord-

set and properly terminated.

• Installation of transient (arc) suppressors across the coils of MPCE1 and MPC2 is recommended.
• See

Single-Ended (Machine Interface) Cordsets

on page 57 for available cordset information

Other interfacing modules and solutions are available, see

Accessories

on page 57.

WARNING: Use of Transient Suppressors

If transient suppressors are used, they MUST be installed across the coils of the machine control ele-
ments. NEVER install suppressors directly across the contacts of the IM-T-..A Module. It is possible for
suppressors to fail as a short circuit. If installed directly across the contacts of the IM-T-..A Module, a
short-circuit suppressor will create an unsafe condition