Wiring, Connection to the machine to be controlled, Auto reset manual reset – Banner ES-FA-6G Safety Module User Manual

Page 7: Figure 4. dual-channel e-stop applications, Figure 5. single-channel e-stop applications

Advertising
background image

WARNING: Reset Routine Required
U.S. and international standards require that a reset routine be performed after clearing the cause of a
stop condition (for example, arming an E-stop button, closing an interlocked guard, etc.). Allowing the
machine to restart without actuating the normal start command/device can create an unsafe condi-
tion which could result in serious injury or death.

NOTE: The minimum time required for the Module to be in a STOP or OFF condition is 250 ms. This “recovery time” (OFF-state) is
required for the internal circuitry of the Safety Module to normalize, allowing a reliable reset to occur. A lockout occurs if the Module is
cycled too quickly. To clear the lockout, the Module must be recycled, meeting the minimum OFF time requirements.

Wiring

24V ac/dc

MSC1

E-Stop
Switch

E-Stop
Switch

Reset

MSC3

MSC2

See WARNING

Below

MSC
Monitor
Contacts
or
Jumper

A2

A1

S34

S33

S21

S11

S12

S22

dc common

+V

ES-FA-9AA

24V ac/dc

Auto Reset

Manual Reset

A2

(No Connection)

A1

S34

S11

S33

MSC1 MSC2 MSC3

S22

S12

S21

dc common

+V

ES-FA-9AA

Figure 4. Dual-Channel E-Stop Applications

24V ac/dc

MSC1 MSC3

MSC2

See Interfacing MSCs

Warning

MSC
Monitor
Contacts
or
Jumper

A2

A1

S34

S33

S21

S11

S12

S22

dc common

+V

ES-FA-9AA

24V ac/dc

Auto Reset

Manual Reset

A2

(No Connection)

Reset

A1

S34

S11

S33

MSC1 MSC2 MSC3

S22

S12

S21

dc common

+V

ES-FA-9AA

E-Stop
Switch

E-Stop
Switch

Figure 5. Single-Channel E-Stop Applications

Connection to the Machine to be Controlled

The machine hookup diagram shows a generic connection of the Safety Module's redundant output circuits to the master stop control
elements (MSCs). An MSC is defined as an electrically powered device, external to the Safety Module, which stops the machinery being

ES-FA-9AA and ES-FA-11AA E-Stop Safety Modules

P/N 060606 Rev. F

www.bannerengineering.com - tel: 763-544-3164

7

Advertising