This section explains how to verify connections, start the PresencePLUS Pro program, and troubleshoot possible
problems.

System Startup

1) Verify cable connections.

- The camera and controller are connected to the camera cable.
- The controller is connected to a PC with an Ethernet crossover cable or serial cable.
- The monitor (if one is being used) is connected to the video port on the controller.

2) Verify electrical connections.

- +V is connected to Pin 1 (10–30V dc).
- –V is connected to Pin 2 (dc common).
- The trigger device is connected to Pin 3 (Trigger In).
- Any additional connections are made as required.

3) Verify lighting.

If lighting is powered by the controller, the strobe wire is connected to Pin 4 (Strobe Out).

4) Verify PC configuration.

- Ethernet connection: IP address of PC is 192.168.0.2
- Serial connection: A dial-up network has been established, and the network is a

point-to-point protocol (PPP).

5) Power up the system.

Verify that the error light turns OFF (during power-up, all controller LEDs illuminate for 15 to 20 seconds). After
the error light turns OFF, verify that the camera LED is flashing.

6) Launch the software.

- Click Start > PresencePLUS Pro to start PresencePLUS Pro.
- If PresencePLUS Pro has a different IP address than the default address (192.168.0.1),

or if it is connected through a serial connection, the message shown below will appear.

- Click Yes to access the

Camera Select Tab

(which follows on page 20).

----------------------------------------------------------------------------------------

--------------------------------------------------------------