Safety mat system periodic checkout procedure, Troubleshooting – Banner Safety Mat Monitoring Modules User Manual

Page 12

Advertising
background image

9. Close and secure the enclosure. Apply power to the machine control elements and perform the following Periodic Checkout Proce-

dure.

Safety Mat System Periodic Checkout Procedure

Verify the functioning of the safety mat monitoring system periodically to ensure proper operation (see also the machine manufacturer’s
recommendations).

WARNING:
Checkouts for Multiple Safety Devices. If more than one safety mat is series-connected to one Safety Mat
Monitor Module, run this checkout procedure individually for each mat.

1. With the machine running, apply force to the mat’s sensing area, using a test piece as described in the mat manufacturer’s literature,

or the appropriate standard. Verify that the machine stops within the expected time period.

2. Remove the test piece from the safety mat. Verify that the machine does not restart.
3. Close and then open the Reset switch (if using Manual Reset mode). Verify that the machine cycle can be restarted by normal initia-

tion.

4. Repeat for each safety mat individually.

Troubleshooting

Use the LED display to help diagnose the problem. After fixing the fault:

• Manual Reset configured — step ON and OFF the mat to clear the lockout.
• Auto Reset configured — the outputs turn ON immediately.

The Fault LED turns OFF if the proper repair has been made.

Condition

Indicator Status

Possible Causes or Solution

Module will not reset

Power LED ON

Waiting for manual reset:

• EDM monitoring contacts are not closed. Check MSCs.
• Check jumper at S32-S35 (auto reset) or S32-S33 (manual reset).
• Check reset button connection.

Fault LED OFF

Ch1 LED Flashing

Ch2 LED Flashing

No fault indicated

Power LED ON

Safety mat appears actuated:

• Check mat for damage or heavy debris.
• Check for proper wiring.
• Check for a short in the wiring.

Fault LED OFF

Ch1 LED OFF

Ch2 LED OFF

No fault indicated

Power LED ON

Channel 1 open:

• Check wiring to S11-S12.
• Check connectors are properly seated.

Fault LED ON*

Ch1 LED OFF

Ch2 LED ON

No fault indicated

Power LED ON

Channel 2 open:

• Check wiring to S21-S22.
• Check connectors are properly seated.

Fault LED ON*

Ch1 LED ON

Ch2 LED OFF

Fault

Power LED ON

Possible temporary fault:

SM-xA-5A Safety Mat Monitoring Modules

12

www.bannerengineering.com - tel: 763-544-3164

P/N 122364_Web

rev. C

Advertising