Installation – Briggs & Stratton 71017 User Manual

Page 12

Advertising
background image

INSTALLATION

12

4.

As shown in Figure 7, cut, strip, and connect each
wire to the appropriate terminal on the locking
receptacle on the inlet box inner panel. Use the
schematic affixed to the inside of the inlet box to
make proper wire connections. When all
connections have been made, reinstall the inlet
box inner panel.

Connecting Cord Set

From the two 120/240 Volt connection plugs supplied
with the transfer switch, select the one that mates to
the generator. Referring to the image in Figure 8 and
the schematic in Figure 9 or Figure 10 that applies to
the connector being used, properly attach the plug to
the pigtail end of the connecting cord set.

Figure 9 — 20A Cord Set Connector

4-Wire Cord Set

240V

120V

120V

W (Neutral)

X (Hot)

Y (Hot)

NEMA L14-20

Ground (Green)

Figure 10 — 30A Cord Set Connector

4-Wire Cord Set

240V

120V

120V

W (Neutral)

X (Hot)

Y (Hot)

NEMA L14-30

Ground (Green)

Figure 8 — Receptacle Connection

Figure 7 — Inlet Box Connections

Advertising
This manual is related to the following products: