I.S. 19-50E

hanging instructions

I.S

. 19-50E

start here

Drawing 1 - Fixture Assembly

Drawing 2 - Installation Example

A

B

C

F

D

E

L

M

top center
knockout

J

K

wire

ceiling
joist

ground

wire
from fixture

ceiling
joist

support
block

junction
box

bridge

supply wire

hex nut

3/8 NPS threaded tube

1. Shut off electrical current before starting. If the fixture you are replacing is
turned on and off by a wall switch, simply turn the switch off. If not, remove
the appropriate fuse (or open the circut breakers) until the fixture is dead.
• DO NOT RESTORE CURRENT - EITHER BY FUSE, BREAKER, OR SWITCH -
UNTIL THE NEW FIXTURE IS COMPLETELY WIRED AND IN PLACE.

2. Supply wires shall enter the outlet box (A) through any knockout EXCEPT
the top center knockout - see Drawing 1.

1. Fixture is to be mounted by a 1/4 IP steel pipe. Pipe should be anchored support

bridging member with sufficient strength to support 4 times the fixtures
weight - see Drawing 2.
2. Adjust pipe so 1/2” of 1/4 IP steel pipe extends into the junction box, at the
center knock out.

1. Thread pipe coupler (B) onto protruding pipe inside outlet box. Secure in place by
tightening allen head screw (C) - see Drawing 1.
2. Thread hexnut (D) onto threaded nipple (E). Thread nipple (E) into coupler (B).
Secure in place by tightening hexnut (D) against coupler (B) and then tightening
allen screw (F).
3. Thread hexnut (J) onto nipple (E). DO NOT tighten hexnuts (J) at this time.

4. Thread screw collar loop (K). Adjust loop height so the half of the exterior thread
on screw collar loop (K) is exposed when canopy (L) is held up to the ceiling.

1. Determine length of chain you will require. Attach one end of length of chain to fixture.
2. Slip threaded ring (M) and canopy (L) onto chain - see Drawing 1.
3. Attach fixture with chain to screw collar loop (K). Please get assistance, weight and
size of fixture is difficult to manage alone.
4. Weave ground wire, and supply wire, and safety cable through chain, up through center
of screw collar loop (K), through center of nipple (E), and out the opening on the side
of coupler (B).

ground

wire

5. Make electrical connections from supply wire to fixture lead wires. Refer to instruc-
tion sheet (I.S. 18) and follow all instructions to make all necessary wiring connections

6. After connections are made slip wires into junction box. Slip canopy along chain and
up to ceiling. Thread thread ring (M) onto loop and tighten to secure canopy to
ceiling.

safety cable

NOTE: Please to safety cable installation instructions on sheet to
complete step 4.