IV.

REPLACEMENT PARTS LIST

Part Number

Description

Quantity per

System

S25FVS720

Pre filter housing 7 round 20"

1

R24449

Pressure Gauge, 2 1/2", 0-100 psi, LF

2

R2452P

Pressure Gauge, 2 1/2", 0-400 psi, LF, Back Mount

1

R2452

Pressure Gauge, 2 1/2", 0-400 psi, LF, Bottom Mount

2

R5397

Flow Meter 1-30 gpm (product)

1

R5142

Flow Meter 1-17 gpm (reject)

1

R5138

Flow Meter 0.5 – 5 gpm (reject recycle)

1

R23-3511 Controller

with

conductivity meter (optional)

1

R6316-V40B12S3T Pump & Motor, 3-Phase, 60Hz, 10 hp

1

R2316-214B

Low Pressure Switch

1

R6154-24V

Inlet Solenoid Valve 24 volt

1

R9640-TM

RO Membranes

16



V. MEMBRANE REPLACEMENT


1. Turn off the system and close the feed water shutoff valve.
2. Disconnect the membrane feed hoses by loosing the brass fittings between the end of

the hoses and the pressure vessel end caps.

3. Remove the retaining rings from the pressure vessels.
4. Push the old membrane out of the vessel in the direction of the feed flow.
5. Record the serial numbers of the new membranes.
6. Lightly lubricate the brine seals on the new membranes with clean water.
7. Install the new membranes in the direction of flow with the brine seal end going in

last.
Note: Be sure to install an interconnector between the membranes in each
pressure vessel.

8. Lightly lubricate the end cap internal and external o-rings with glycerin.
9. Install the end caps and secure them with the retaining rings.
10. Install the membrane feed hoses.
11. Verify that all retaining rings are installed.
12. Follow the start up procedure in section III-D.


Flow Direction

Membrane Brine Seal