A. Specifications

R44-16 R44-20

R24-24

Maximum Productivity

(Gallons per day / Gallons per minute)

Maximum production based on standard membranes and feed water of
25°C, SDI < 3, 1000 ppm TDS, and pH 8. Individual membrane
productivity may vary (± 15%). May be operated on other feed waters
with reduced capacity.

28,800 / 20

36,000 / 25

43,200 / 30

Quality

(Typical Membrane Percent Rejection)

Based on membrane

manufactures specifications, overall system percent rejection may be less.

98 %

98 %

98 %

Recovery (without reject recirculation)
Recovery (with reject recirculation, depending on feed water)

70 %
75 %

70 %
75 %

70 %
75 %

Membrane Size

4 x 40

4 x 40

4 x 40

Number Of Membranes Per Vessel

4 4

4

Pressure Vessel Array

2:2 3:2

4:2

Number Of Membranes

16 20

24

Prefilter Housing

(System ships with one set of 5 micron cartridges)

7 round x 20”

7 round x 20”

7 round x 20”

Feed Water Connection

2" NPT

2" NPT

2" NPT

Product Water Connection

1 1/2" NPT

1 1/2" NPT

1 1/2" NPT

Reject Water Connection

1" NPT

1" NPT

1" NPT

Feed Water Required

Feed water required will be less if reject recycle is used.

29 gpm

36 gpm

43 gpm

Feed Water Pressure

(Minimum)

20 psi

20 psi

20 psi

Drain Required

29 gpm

36 gpm

43 gpm

Electrical Requirement

230 VAC, 3-ph, 60 Hz (Other voltages available)

30 amps

30 amps

30 amps

Multistage Centrifugal Pump

(Model)

V40B12 V40B12

V40B12

TEFC Motor

(Horse Power)

10 10

10

Dimensions L x W x H

(Ft.)

16 x 3 x 6

16 x 3 x 6

16 x 3 x 6

Shipping Weight

(Estimated Pounds)

1400 1600

1800