Danger – Bard Oil Furnace FLF085D36F User Manual

Page 36

Advertising
background image

Manual 2100-422N
Page

36 of 42

TO REMOVE BURNER ONLY

Disconnect fuel line, power cord and wires from T, T
on primary control. Loosen (3) 1/4 inch bolts securing
burner mounting flange. Twist burner
counterclockwise and pull straight back away from the
furnace. (See Figure 19.)

TO REMOVE THE ENTIRE COMBUSTION
CHAMBER MOUNTING SYSTEM

Disconnect fuel line, power cord and wires from T, T
on primary control. Remove (6) 5/16 inch bolts from
around front plate. Next remove (2) 5/16 inch nuts
from upper right and left hand corners of the front
plate. Pull entire assembly straight back away from
furnace. BE CAREFUL NOT TO TIP ASSEMBLY
UP OR DOWN AS IT MAY DAMAGE THE
COMBUSTION CHAMBER. (See Figure 20.)

BURNER AND COMB. CHAMBER

MOUNTING SYSTEM

REMOVAL INSTRUCTIONS

STEP 1:
DISCONNECT "T-T" WIRES,
POWER CONNECTIONS, AIR
BOOT (OPTIONAL) AND OIL
LINES TO BURNER.

STEP 3:

REMOVE (2) NUTS

IN THE TOP LEFT

AND RIGHT CORNERS

OF BURNER PLATE.

STEP 2:
REMOVE (6) BOLTS
AROUND PERIMETER
OF BURNER PLATE

STEP 4:
PULL BURNER ASSEMBLY
STRAIGHT OUT TO PREVENT
DAMAGE TO CHAMBER
DURING REMOVAL.

MIS-1837 A

BURNER
PLATE

CHAMBER

*ELECTRICAL SHOCK HAZARD
*DISCONNECT POWER BEFORE
SERVICING.

DANGER

!

FIGURE 20

REMOVAL OF ENTIRE COMBUSTION CHAMBER MOUNTING SYSTEM

Advertising