Instructions for the installer

26

5.2 Regulation for LPG

Loosen screw A and push support B all the way. Use a double head
wrench to remove nozzle C and assemble the suitable one, following the
instructions indicated in the reference charts, with respect to the type of
gas to use. The screwing torque of the nozzle should never exceed
3 Nm. Reposition support B so that nozzle C is covered perfectly.
Move the Venturi tube D to regulate the air flow until distance "X" is
reached indicated in the chart in paragraph "5.4 Regulation of primary air”
and then secure the tube by means of screw A. After the regulations
have been carried out, restore the seals with sealing wax or equivalent
material.














Burner

Rated

heating

capacity

(kW)

LPG – G30/G31 28/37 mbar

Nozzle

diameter

1/100 mm

By-pass

mm

1/100

Reduced

flowrate

(W)

Flowrate

g/h G30

Flowrate

g/h G31

Auxiliary (1)

1.05

48

30

33 (*)

380

76

75

Semi-rapid (2)

1.65

62

30

33 (*)

380

120

118

Average rapid (3)

2.55

76

37

40 (*)

750

185

182

Large rapid (4)

3.1

85

45

800

225

222

Triple crown (5)

3.9

95

65

1700

283

279

Triple crown (6)

3.3

87

65

1700

240

236

internal (7)

0.8

42

26

33 (*)

380

58

57

Double crown

external (7)

3.3

87

55

1200

240

236


(*) By-pass value for valveless appliances.