Instructions for the installer, 3 regulation for natural gas, 4 regulation of primary air – Bosch NET 682 C User Manual

Page 12: Referred to distance “ x ” in mm

Advertising
background image

Instructions for the installer

27

5.3 Regulation for natural gas

The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.2 Regulation for LPG”, but choose
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph “5.4 Regulation of primary air”. After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.


Burner

Rated heating

capacity

(kW)

Natural gas – G20 20 mbar

Nozzle diameter

1/100 mm

Reduced flowrate

(W)

Auxiliary (1)

1.05

73

380

Semi-rapid (2)

1.65

92

380

Average rapid (3)

2.55

115

750

Large rapid (4)

3.1

126

800

Triple crown (5)

3.9

140

1400

Triple crown (6)

3.3

130

1400

internal (7)

0.8

67

380

Double crown

external (7)

3.3

130

900



5.4 Regulation of primary air

Referred to distance “X” in mm.


BURNER

G20

20 mbar

G30/G31

28/37 mbar

Auxiliary (1)

1.5

1

Semi-rapid (2)

1.5

1.5

Average rapid (3)

1

1.5

Large rapid (4)

1.5

2.5

Triple crown (5)

2

3.5

Triple crown (6)

1

2.5

internal (7)

0.5

1.5

Double crown

external (7)

1

4