Installation Instructions for Type A HN-400 Column Shower

Step 1: Install column shower components

NOTE: Flush supply lines before making connections.

1. Remove the five bolts that secure the disposable washer to

the drain and lift the disposable washer off.

2. Bolt the column shower to the drain with the five bolts

(removed in procedure #1) and oval washers provided (see
Figure 1).

Step 2: Connect water supply

1. Remove the two 1/4"-20 screws from the access panel on

the lower body of the column shower and lift the panel off.

2. Through the access opening, connect water supplies to the

shower’s 3/4" copper tubing as shown in Figure 2 (piping
supplied by installer).

3. Turn on water to the shower and test for leaks and adequate

water flow.

4. Replace the access panel onto the shower with 1/4"-20 screws provided.

NOTE: For column shower drains with a dome grate drain, install the two halves of the grate with
the screws provided after the column installation is complete.