Step 1: install column shower components, Step 2: connect water supply – Bradley Smoker HN-400 User Manual

Page 5

Advertising
background image

5

Bradley Corporation • 215-781 Rev. D; EN 03-310

Barrier-Free Column Shower

Installation Instructions

HN-400

12-16-2003

Installation Instructions for Type H HN-400 Column Shower

Step 1: Install column shower components

NOTE: Flush supply lines before making connections.

1. Remove the five bolts that secure the disposable washer to

the drain and lift the washer off.

2. Loosen the screw(s) securing the shower’s cover and lift the

cover off. DO NOT remove the screw(s)!

3. Insert a 2" NPT vent pipe (supplied by installer) into the shower.

NOTE: Make sure that the vent pipe does not snag internal wiring
or come in contact with the electronic components.

4. Position the shower over the drain and screw the 2" NPT vent

pipe into the vent connection (see Figure 6).

5. Bolt the shower to the drain with the five bolts (removed in

procedure #1) and oval washers provided (see Figure 5).

Step 2: Connect water supply

1. Remove the two 1/4"-20 screws from access panel on lower

body of column shower and lift panel off.

2. Through access opening, connect water supplies to the shower’s 3/4" copper tubing as shown in

Figure 6 (piping supplied by installer).

3. Slide column cover over vent.

NOTE: If you are installing a column shroud, slide the slip ring up the vent and supply piping first,
and then slide column cover up (see page 7 for shroud installation).

4. Turn on water to the shower and test for leaks and adequate water flow.

5. Replace access panel onto shower with the 1/4"-20 screws provided.

NOTE: For column shower drains with a dome grate, install the two halves of grate with the screws
provided after the column installation is complete.

(5) 5/16"-18

HEX-HEAD

BOLTS

160-092

(5) WASHERS

142-034

Figure 5

Figure 6

Supplies from Below/Vent Through Column

Advertising