4. Selecting frequencies and power output

FREQ SELECT switch is equipped on both TX and RX. POWER MODE
switch is located on TX side only.
FREQ SELECT switch is used to select transmission and receiving
frequency.
FREQ SELECT switch must be same position on both TX and RX.
POWER MODE switch enables you to change the transmission power,
HIGH or LOW.

4.1. Available frequencies and transmission power

The table shows the available frequencies and transmission power for U.S.
region.

Channel
position

frequency

(MHz)

Limitation of use

Transmission power

HIGH

LOW

CH1

5190MHz

Indoor

12.5mW

/Ant.

5mW/Ant.

CH2

5230MHz

Indoor

CH3

5755MHz

Indoor/Outdoor

20mW/Ant.

CH4

5795MHz

Indoor/Outdoor

DFS AUTO

Outdoor use allowed with DFS

ON

Automatically select from

following frequencies.

5270,5310,5510,5550,5670

MHz

Indoor/Outdoor

System

initialization

(link time) will

take one minute

There is a strict regulation allowing certain frequencies for indoor use only.
Please note that uses of unauthorized frequencies outdoors may be a
violation of the law.