Control panel operation – Klimaire KTHM015-E5H2 PTAC Installation Manual User Manual

Page 7

Advertising
background image

6

CONTROL PANEL OPERATION

The control pane l ke ypad will look like th e fo llowing
Fig.1:

HIGH MED LOW

FAN COOL HEAT

POWER

POWER
-
Press the POW ER button to turn the unit on or off.

W hen the unit is on,the power indicator light will be
green.When the unit is off,the light will go out.

MODE
-
Push this button to cycle through the modes from

COOL-HEAT-FAN-COOL.The indicator light beside
the "M ODE" option will illum inate, ide ntifying the
mo de selected.

- COO L :The rang e of set temp e rature is 17 C/62 F

~30 C/86 F.Cooling beg ins au tom atically when the
room temperature is ab ove the set point,and stops
when the room temperature is 2 C(4 F) below the
set point.But the comp ressor will run 5 m inutes at
least in COOL m ode be fore stoping. The fan runs
in continu ous mode.

- HEAT:The range of set temperature is 17 C/62 F

~29 C/84 F.For hea t pump mo dels,th e unit can
alternate to run between in reverse cycle heat mo de
and electric heater mo de a ccording to the difference
between the setting tem perature and the room
tempe rature.The fan motor cycles on and off
with th e compressor an d electric hea ter.
NOTE: The reverse cycle and electric he ater can
not be run at the sam e time.

- FAN:F an ope ration only without heating and cooling.

O

O

O

O

O

O

O

O

O

O

UP/DOWN BUTTONS (

/

)

- Push the UP (or DOWN) button to increase (or

decrease) the set te mperature of the unit in coo ling
or heating mode.The te mperature can be se t by
increm ents of 1 C (1 F).Th e setting temperature
appea rs in the display.
NOTE:Press and ho ld

and

buttons toge ther

for 3 seco nds will alternate the tempe rature display
between C & F scale.

O

O

O

O

FAN (FAN SPEED)
-
Every time you pu sh this bu tton ,the fan sp eed

cycles through the settings as follows:HIGH-M ED-
LOW -HIGH.

Fig.1

DISPLAYS:
-

-

Shows the set tem perature in C or F. While on

Fan on ly m ode ,it shows the room temperature.

Pads o n the control pan el is no t available .The
unit ca n be setted by using wire cotroller only.

Room temp eratu re sensor error;

Evapo rator temperature sensor error;

Condense r te mp erature senso r error;

Ou tside tempe rature se nsor error;

Exhaust tempe ra ture sen sor error;

NOTE:Whe n error occurs,u nplug the unit and plug

it back in.If error repe ats, call for service.

Room tem perature is lo wer tha n 0 C/32 F;

Room temp erature is higher tha n 37 C/99 F.

O

O

O

O

O

O

Control code (on some models):
LC

Error codes:

AS-

ES-
CS-
OS-
HS-

Other codes:
LO-
HI-

Advertising