Warranty, Maintenance and troubleshooting – Powers PB410 Series Pressure Balancing Mixing Valves - Pressure Balancing Mixing Valve User Manual

Page 4

Advertising
background image

Warranty

n

The Seller warrants that the equipment manufactured by it and covered by this order or contract is free from defects in material and workmanship and, without

charge, equipment found to be defective in material or workmanship will be repaired, or at Seller’s option replaced F.O.B. original point of shipment, if written

notice of failure is received by Seller within one (1) year after date of shipment (unless specifically noted elsewhere), provided said equipment has been properly

installed, operated in accordance with the Seller’s instructions, and provided such defects are not due to abuse or decomposition by chemical or galvanic action.

ThiS expreSS warranTy iS in lieu OF and excludeS all OTher warranTieS, guaranTeeS, Or repreSenTaTiOnS, expreSS OF implied. There are

nO implied warranTieS OF merchanTaBiliTy Or OF FiTneSS FOr a parTicular purpOSe. The Seller assumes no responsibility for repairs made on the

Seller’s equipment unless done by the Seller’s authorized personnel, or by written authority from the Seller. The Seller makes no guarantee with respect to material

not manufactured by it.

Maintenance and Troubleshooting

n

USA:  Phone: 1.800.669.5430 • Fax 1.847. 229.0526 • www.powerscontrols.com

Canada:  Phone: 1.888.208.8927 • Fax 1.888.479.2887 • www.powerscontrols.ca

IS-P-PB410 1232

EDP# 6512297

© 2012 Powers

A Watts Water Technologies Company

What to look for if:
• The flow of water is less than desired.
a. Valves upstream from supply not fully open.
b. Low supply pressures.
c. Accumulation of lime deposits in hot water pipes, restricting

the flow of hot water.

d. Showerhead clogged.
e. Checkstops may not be fully open.
f. Low supply temperature (Hot Water).
• Flow of water is completely shut off.
a. Valves upstream from supply completely closed.
b. Failure of hot or cold water supply pressure. The

HydroGuard

®

is constructed to restrict the flow of water on

hot or cold water supply failure.

c. Checkstops closed.
• Flow is untempered hot or cold water.
a. The water supplies are connected to the wrong ports.
b. Check for foreign material that may be clogging the car-

tridge.

• Flow of water continues when HydroGuard

®

is

shut off.

a. Worn shutoff discs. Replace cartridge.
b. Scratched mixing plate. Replace Bonnet/Stem Kit.
c. Erosion. Contact a Powers applications engineer to order

replacement parts.

• Maximum temperature is too low.
a. Accumulation of lime deposits in hot water pipes, which

restricts the flow of hot water.

b. The concealed maximum temperature limit stop is not at its

maximum adjustment. Set the maximum temperature limit

stop.

c. Hot water temperature is too low.