Onnecting the cables, Ligning the finderscope, Ocusing – Sky-Watcher DOB16 User Manual

Page 10

Advertising
background image

108

C

onnecting the cables

Power supply cable: The Dobsonian SynScan requires

12-Volts DC Nominal power. The power cable from the

battery pack or other power supply goes into the jack labeled

Power on the altitude motor box. (Fig.a).

AZ motor cable: This is the flat cable with 8-pin RJ-45 plug on

both end. Insert one end into the jack labeled "Az Motor" on

the altitude motor box and the other end into the azimuth

motor box on the round base.
Hand control cable: This is the coil cable with a 8-pin RJ-45

plug on one end and a 6-pin RJ-12 plug on the other. Plug the

RJ-45 end into the hand control (Fig.e) and the other end into

the outlet on the altitude motor box (Fig.a).

Fig.b

Fig.c

A

ligning the Finderscope

These fixed magnification scopes mounted on the optical tube are very useful

accessories. When they are correctly aligned with the telescope, objects can

be quickly located and brought to the centre of the field. Alignment is best

done outdoors in day light when it's easier to locate objects. If it is necessary

to refocus your finderscope, sight on an object that is at least 500 yards

(metres) away. Loosen the locking ring by unscrewing it back towards the

bracket. The front lens holder can now be turned in and out to focus. When

focus is reached, lock it in position with the locking ring (Fig.b).

Choose a distant object that is at least 500 yards away and

point the main telescope at it. Adjust the telescope so that

the object is in the centre of the view in your eyepiece.

Check the finderscope to see if the object centred in the

main telescope view is centred on the crosshairs.

Use the two small alignment screws to centre the

finderscope crosshairs on the object. The screws work in

opposition to a spring-loaded knob (Fig.c).

1.

2.

3.

(Straight through finderscope

shown here)

F

ocusing

Slowly turn the focus knobs (Fig.c), one way or the other, until the

image in the eyepiece is sharp. The image usually has to be

finely refocused over time, due to small variations caused by

temperature changes, flexures, etc. This often happens with short

focal ratio telescopes, particularly when they haven't yet reached

outside temperature. Refocusing is almost always necessary

when you change an eyepiece or add or remove a Barlow lens.

Fig.c

To avoid tangling of the power cable, the battery pack or

power tank can be placed on the round base, behind the

front panel. Pass the cable through the first hole on the

left side panel to plug into the power jack.

Fig.a

Hand control

cable goes here

Hand control

holder

Power switch

AZ motor cable

goes here

Power cable

goes here

Altitude motor box

Advertising