Sing the user defined database – Sky-Watcher DOB16 User Manual

Page 20

Advertising
background image

20

18

Auto Tracking - Allows the telescope to automatically track a celestial object without star

alignment. The hand control will display the coordinates of the direction the telescope is pointed at.

You may press the scroll keys to switch the coordinate to a different mode.

Set Slew Limits - Allows you to set the slewing limits of the mount on altitude axis. Setting the slew

limit prevents the optical tube from colliding with mount. To set the slew angular limitations in

altitude, use the numeric keys to enter the degrees and the RIGHT or LEFT keys to move the

cursor. The slew limit range is dependent on the mount and the optical tube installed on the mount.

Re-align Encoder - There are two encoders built in each axis of the Sky-Watcher Dobsonian Pro

mount. One encoder is coupled to the axis shaft and the other coupled to the motor shaft. This dual

encoder design (US Patent #: 7,228,253) allows you to manually move the telescope by hand any

time without losing the count on the axis encoder as long as the power is on. This enables the

Dobsonian to perform the Go-To and Autotracking functions to a certain degree of accuracy.

However, since the encoder at the axis shaft has lower resolution than the encoder coupled on the

motor shaft, you may need to calibrate the encoders from time to time to secure Go-To accuracy.

Following these steps to re-align the encoders:

Sid. Rate: This activates tracking in Sidereal rate (Dual Axes Tracking).

Lunar Rate: This activates tracking in Lunar rate (Dual Axes Tracking).

Solar Rate: This activates tracking in Solar rate (Dual Axes Tracking).

Stop Tracking: This stops the tracking instantly.

RIGHT directional key to move the cursor to the next digit. First set the value for R.A. Press

ENTER to proceed to Dec.

Tracking

Handset Setting - This submenu allows adjustments of the brightness of the LCD backlit, the

darkness of the LCD lettering, the brightness of the LED backlit and the beeper volume. Press the

RIGHT or LEFT directional key to increase or decrease the value.

Factory Setting - This submenu allows you to reset the hand control to its default setting.

The slew limit can be set any time but it will come into effect only until the star alignment has

been performed.

1.

2.

3.

4.

Choose Re-align Encoder under SETUP menu. Press ENTER to start.

The hand control will prompt you the two alignment starts chosen during the previous

star-alignment procedure. Use the scroll keys to select one of them and press ENTER to confirm.

The telescope will slew to the selected reference star. Use the directional keys to put the star in

the center of the eyepiece field. Press ENTER to confirm.

The hand control will prompt “Re-align Encoder completed.” on the LCD screen. Press ENTER to

confirm and finish the Re-align Encoder procedure.

The accuracy of the SynScan system depends heavily on the initial set up and star alignment. If you

notice inaccuracy in the Go-To performance, make sure that the initial set up and star alignment are

done correctly before considering re-aligning the encoders.

Find the User Objects under the Object Catalog. Press ENTER.

1.

Choose Edit Object by using the scroll keys. Press ENTER.

The SynScan™ AZ hand control stores the user-defined objects in two

formats - RA-Dec and AzAlt. Choose your desire format by pressing 1

for RA-Dec or 2 for Alt-Azimuth.

1.

2.

Saving an object to the database

U

sing the User Defined Database

SynScan

TM

AZ allows you to save up to 25 objects in the user defined database.

Fig.k

The User Defined menu can also be accessed by pressing the quick

reference hot key “USER” (Fig.k).

Advertising
This manual is related to the following products: