- Data Brochure

Universal Reset Control 374

D 374

03/09

1

of

36

©

2009 D

374

-

03/09

Universal Reset Control 374

Two Mixing, Two Stage Boiler, DHW & Setpoint

Signal wiring must be rated at least 300 V.

1

Opn

Var1

Var2

1

Mix

2

Sw

P2

L

N

P1 P3

N

Pmp/Vlv

Dem Dem Dem Dem Dem Dem Dem

2

Cls1 Pwr Opn Cls2

UnO Com Boil Out Com Mix1 Mix2

Mix1 Power

DHW

Prim Mix2

Mix1 Com Mix2 Setp DHW Boil Com

3 4 5

6 7 8 9 10 11 12

15

16 17

18

Boil Enbl.

Stage 1/

Setp Enbl.

Stage 2/

19 20 21 22 23 24 25 26 27

29

28

30 31

Do not apply power

13 14

Boiler Demand
Mix 1 Demand
Mix 2 Demand
DHW Demand
Setpoint Demand

Test

off

not testing

red

testing

red

testing paused

Made in Canada by

tekmar Control Systems Ltd.

Power:

115 V ±10% 50/60 Hz 1750 VA

Relays:

230 V (ac) 5 A 1/3 hp, pilot duty 240 VA

Variable Pump: 230 V (ac) 2.4 A 1/6 hp, fuse T2.5 A

Demands:

20 to 260 V (ac) 2 VA

Boiler Sensor

Variable

Off

Supply

Installer

Advanced

Setback

30% Enable

10% Enable

Return

Rotate

Floating

H2036B

Menu

Item

Input

Universal

Sensor

Included

Input

032 Timer

Optional

Input

Universal

Sensor

Included

Input

Universal

Sensor

Included

Output

Boiler

Output

Primary

Pump

Input

115 V (ac)

Power

Supply

Input

Outdoor

Sensor

Included

Input

Boiler

Demand

Input

DHW

Demand

Input

Setpoint

Demand

Input

Mix 2

Demand

Input

Mix 1

Demand

Output

Mix 1

System

Pump

Output

Mix 2

System

Pump

Output

DHW

Pump

Output

DHW

Valve

Output

Variable

Speed

driven

pump

Output

Mixing

Valve &

Actuating

Motor

OR

OR

Output

Variable

Speed

driven

pump

Output

Mixing

Valve &

Actuating

Motor

OR

For maximum heat,
press & hold Test
button for 3 seconds.

Meets Class B:
Canadian ICES
FCC Part 15

Dat

e Code

Note:
Boiler, DHW,
setpoint, or mixed
demand must be
powered with 20 to
260 V (ac) before
the control will
operate pump/valve
outputs or the boiler
is able to fire.

The tekmar Universal Reset Control 374 is designed to maximize the comfort and effi ciency provided by a hydronic heating system. The
control automatically adjusts the boiler and mix water temperatures that are delivered to the heating system by using outdoor reset. The
374 can control two separate on / off stages (or one low / high fi re) to provide outdoor reset while providing equal run time rotation of the
boilers. The 374 can operate two mixing devices, which can be either two variable speed injection pumps or two fl oating action valves.
The mixing devices can be used to supply two different reset water temperatures or one reset and one setpoint water temperature to a
space heating system. The 374 is capable of controlling an indirect Domestic Hot Water (DHW) storage tank and setpoint load. A large
easy to read display provides current system temperatures and operating status. The control has an internal timer, which can have 2
events per day on a 24 hour, 5-1-1 day or 7 day schedule.

• Installer and Advanced access levels
• Primary pump and mixing system pump outputs
• Exercising
• Test sequence to ensure proper component operation
• Internal setback timer for energy savings
• Setback input for energy savings
• CSA C US certified

Additional functions include:

• Outdoor

Reset

• Two Mixing Devices
• Two Boiler Stages
• Two separate mix demands for space heating loads
• Boiler demand for space heating loads
• DHW demand for domestic hot water loads
• Setpoint demand for setpoint loads