tekmar 541 Thermostat User Manual

Page 12

Advertising
background image

© 2007

D 541 - 08/07

12 of 24

Adjusting the Room Set Temperature (No Schedule)

Section C1

If no schedule is being used, the heating temperature can be permanently adjusted from the View menu when viewing
either the “Room” or “Room Set” items.

Adjusting the Room Set Temperature (Schedule)

Section C2

When using a schedule, the heating temperature for each
schedule event can be permanently changed from the Adjust
menu. There will be one “Set Heat” item in the Adjust menu
for each scheduled event.

In a two event schedule, the events are:

Occ (Occupied)

UnOcc (UnOccupied)

In a four event schedule, the events are:

Wake
UnOcc


Occ
Sleep


When scenes are used, an additional ‘Away’ event is
available.

If a schedule is not in use, only the Set Heat Occ setting
is available.

Wait 10

seconds

Current schedule

status indicates a

schedule is in use

Press Up or Down

Button to adjust the

“Wake” temperature.

Press Up or Down

Button to adjust the

“UnOcc” temperature

Press Up or Down

Button to adjust the

heating temperature.

OR

Temporary Room Set Adjustment (Schedule Only)

Section C3

Pressing the up or down button while viewing the Room
or Room Set temperature during scheduled operation
allows for a temporary change in temperature. When the
temporary change is in effect, the words “TMPY HOLD”
are shown on screen.

The temporary change lasts for 3 hours but can be
cancelled before this by pressing the Up and the Down
buttons at the same time.

Wait 10

seconds

OR

Press Up and Down

buttons at the same

time to cancel the

temporary hold.