Display and dip switches – tekmar 541 Thermostat User Manual

Page 2

Advertising
background image

© 2007

D 541 - 08/07

2 of 24

Table of Contents

Table of Contents ............................................................2
Display and DIP Switches ..............................................2
Dip

Switches

...........................................................2

Access

Levels

.........................................................3

Display and Symbols Description............................3

User

Interface

.........................................................4

Setup ..............................................................................5
View

Menu

.............................................................5

Adjust

Menu

............................................................6

Scene

Menu

............................................................8

Schedule

Menu

.......................................................9

Miscellaneous

Menu

..............................................9

Thermostat Operation .................................................. 11

Auxiliary Sensors ................................................. 11

Mode of Operation ............................................... 11

Adjusting the Temperature ................................... 12

Cycles Per Hour ................................................... 13

Heating Terminal Units ......................................... 13

Heating

Operation

................................................ 14

Cool

Groups

......................................................... 15

Setting the Schedule ............................................. 15

Optimum Start / Stop ........................................... 15

Scenes

................................................................. 16

Away Hold ............................................................ 17

Offset

................................................................... 17

Units of Temperature ............................................ 17

Backlight

.............................................................. 17

tN4

Address

......................................................... 17

Pump

Exercising

................................................... 17

Error Messages ............................................................ 18
Cleaning the Thermostat ............................................. 24
Warranty ....................................................................... 24

Display and DIP Switches

Dip Switches

tN4 System Control (DIP Switch #2)

A tN4 System Control is a control, not a thermostat, that
the 541 thermostat connects to through the tN4 bus. All
tN4 compatible Outdoor Reset Modules are tN4 System
Controls.

• If the thermostat is connected to a tN4 System Control,

set the tN4 System Control DIP switch to tN4 System
Control (down position).

• If the thermostat is not connected to a tN4 System

Control, set the tN4 System Control DIP switch to None
(up position).

Lock / Unlock (DIP Switch #1)

Use the Lock / Unlock DIP switch to lock or unlock the
Access Level of the 541.

• To unlock the Access Level, set the DIP switch to the

unlocked (down) position.

• To lock the Access Level, set the DIP switch to the locked

(up) position. Once locked, a padlock is displayed in the
lower right corner of the display and the Access Level
cannot be changed.

Note: The tN4 System Control’s Lock / Unlock DIP switch
overrides the Lock / Unlock DIP switch on the 541. Set
the tN4 System Control’s Lock / Unlock DIP switch to the
Unlock position before Access Levels can be changed on
the thermostat.