After unpacking, the pump should be checked for any damage that may have
occurred during shipment. Damage should be reported to the carrier
immediately.

The following items should be included within the shipping container:

Qty

Item

Description

1

960E

Mega 960E Pump

1

M960E

Operation/Maintenance Manual

1.2 TIE BOLT TORQUE

The tie bolts on the pump are tightened before leaving the factory. However,
relaxation may occur due to handling, material creep, or other unforeseen
events. Trebor recommends that all eight tie bolts be re-tightened upon pump
install. The following procedure should be used.

1. Remove black tie bolt caps (Item 18 in 4.4 Parts Illustration) from both

sides of all 8 tie bolts.

2. Apply 60 in-lbs. of torque to each slave side bolt while holding the master

side bolt stationary. A star-pattern is advised.

a. The master side is the left side of the pump if you are looking at

the fluid ports.

3. Replace tie bolt caps.

1.3 UTILITIES / HOOK-UP

The pump is mounted using four 1/4” bolts. It is recommended that the pump be
mounted not more than 15

° from level to maintain its self-priming ability and

pumping efficiency.

Air Inlet:

3/8” FNPT (3/8” Dia. [8mm] supply tube minimum).

Air Supply:

25-80 psig (1.4 - 4.1 bar) clean dry air or nitrogen. (For Air
Consumption, See Section 3.1 Performance Charts)

Fluid Ports: Inlet/Outlet Fluid Fittings and Surge Suppressor require torqueing

during pump installation. See Section 2 for hook- up diagram and
torque values.

Remote
Exhaust:

3/8” FNPT (3/8” Dia. minimum tube up to 6’ length, 1/2” Dia.
Minimum tube greater than 6’ length).