3 start-up, 1 high temperature operation, 2 performance charts – Trebor 960E Mega User Manual

Page 8: 3start-up

Advertising
background image

3

START-UP

• Pump air supply pressure should be regulated.
• Open the fluid suction (IN) line valve, if necessary.
• Open the fluid discharge (OUT) line valve, if necessary.
• Start with air regulator at low pressure setting. Increase or decrease air

pressure to attain desired flow, up to 80 psig (4.1 bar).

Table 1: Consumption / Efficiency can be used to determine approximate air

consumption.

• Refer to Troubleshooting, Section 5, if pump fails to start.

ATTENTION: Prolonged periods of dry running (>5 minutes) will damage critical
internal pump parts.

CAUTION: When handling potentially dangerous fluids under pressure,

the pump and its fittings should be placed in an enclosure.

3.1 HIGH TEMPERATURE OPERATION

Pump operation at temperatures above 60°C requires periodic tightening of the
tie bolt nuts. The frequency of this procedure is best established by the user.

3.2 PERFORMANCE CHARTS

Pumping capacity is a function of air supply pressure and volume, suction head,
suction line restrictions, discharge head, discharge line restriction, and fluid
specific gravity and viscosity.

Air Supply

Pressure

(PSIG)

Discharge

Fluid

Pressure

(PSIG)

Air

Used

(SCFM)

Cycles

Per

Minute

Displacement

IN

3

Per

Cycle (Max)

25

2

7.4

108

35

30

3

8.9

116

33

30

10

8.2

100

32

40

5

11.6

152

29

40

20

11.1

108

31

50

10

14.4

156

28

50

30

12.2

104

30

60

20

16.6

156

26

60

50

12.6

94

29

Table 1: Consumption / Efficiency

NOTE: Specification to be used to size regulators and control valves.

PAGE 8

MEGA 960E PUMP OPERATION / MAINTENANCE MANUAL