P20 PUMP OPERATION / MAINTENANCE MANUAL

PAGE 11

7

TROUBLESHOOTING

Pump Will Not Start, Fails to Operate

Cause:

Solution:

Insufficient air pressure

Increase regulated supply pressure or check control
valves for proper operation.

Rotate PC7 speed control screw CW until it stops. Then
readjust for correct speed (if applicable).

Debris in shuttle valve

Inspect/clean control valve assembly.

PC7 (if applicable)

Refer to PC7 Manual

Bubbles in Fluid Discharge

Cause:

Solution:

Inlet line fittings not tight

Check and tighten all fittings on the suction line feeding
the pump.

Flow too high

Under high flow conditions some fluids can cavitate
releasing dissolved air bubbles.

Diaphragm failure due to puncture

Contact Trebor Customer service for additional service
recommendations. Replace pump.

Fluid Leaks

Cause:

Solution:

Weld failure of fluid pump

Replace pump (Non Serviceable)

Fluid leaking from suction or discharge
connections

Inspect tubing and tighten fluid fittings.

Erratic Cycling

Cause:

Solution:

Debris in shuttle valve

Inspect/clean control valve assembly.

PC7 (if applicable)

Refer to PC7 Manual

Advertising