PAGE 8

P20 PUMP OPERATION / MAINTENANCE MANUAL

5

START-UP

Open the fluid suction (IN) line valve, if necessary

Open the fluid discharge (OUT) line valve, if necessary

Pump air supply pressure should be regulated

Operate pump at 20 psig initially to prime pump

Increase pressure to attain desired flow, (not to exceed 80 psig)

If the pump fails to start, refer to the troubleshooting section or contact Trebor for

further assistance.

ATTENTION: Prolonged periods (>5 minutes) of running without fluid can damage critical
internal pump parts.

CAUTION: When handling potentially dangerous fluids under pressure, the pump

and its fittings should be placed in an enclosure away from operators.

5.1 PERFORMANCE CHARTS

Pumping capacity is a function of air supply pressure and volume, suction head, suction
line restrictions, discharge head, discharge line restriction, and fluid specific gravity and
viscosity.

Air Supply

Pressure

(PSIG)

Discharge

Fluid

Pressure

(PSIG)

Flow

(LPM)

Cycles

Per

Minute

Displacement

cc Per

Cycle

Air

Consumption

(CFM)

20

0

14

100

140

4.6

20

10

11

100

110

40

0

18.5

180

103

6.0

40

20

12.5

104

125

60

0

20

210

95

7.0

60

30

15

110

137

80

0

21

218

97

8.0

80

40

16

132

121

Table 5-1: Performance Chart

NOTE: Test information is based on specific conditions and limited sampling. Use for
general reference only. This information is preliminary and may be changed at a future
date.