Carrier AQUAZONE PSV User Manual

Page 15

Advertising
background image

15

*Optional.

AL

Alarm Relay Contacts

ASTAT

Aquastat

BM

Blower Motor

BMC

Blower Motor Capacitor

BR

Blower Relay

CB

Circuit Breaker

CC

Compressor Contactor

CO

Condensate Overflow Sensor

COMPR

Compressor

DTS

Discharge Temp Switch

FP1

Water Coil Freeze Protection Sensor

FP2

Air Coil Freeze Protection Sensor

HP

High-Pressure Switch

HWG

Hot Water Generator

JW

Jumper Wire

LOC

Loss of Charge Pressure Switch

MV

Motorized Valve

NEC

National Electric Code

LEGEND

P1

Field Wiring Terminal Block

RVS

Reversing Valve Solenoid

TRANS

Transformer

Factory Low Voltage Wiring
Factory Line Voltage Wiring
Field Low Voltage Wiring
Field Line Voltage Wiring
Printed Circuit Trace
Optional Wiring

Relay/Contactor Coil

Thermistor

Condensate Pan

Circuit Breaker

Ground

Solenoid Coil

Relay Contacts - N.C.

Relay Contacts - N.O.

Capacitor

Temperature Switch

Low Pressure Switch

High Pressure Switch

Wire Nut

Splice Cap

LED

G

NOTES:

1. Compressor and blower motor thermally protected internally.
2. All wiring to the unit must comply with NEC and local codes.
3. Transformer is wired to 460 v (BLK/RED) lead for 460/60/3 units,

575 v (GRY) lead for 575/60/3. Transformer is energy limiting or may
have circuit breaker.

4. FP1 thermistor provides freeze protection for water. When using anti-

freeze solutions, cut JW3 jumper.

5. Check installation wiring information for specific thermostat hookup.

Refer to thermostat installation instructions for wiring to the unit.
Thermostat wiring must be “Class 1” and voltage rating equal to or
greater than unit supply voltage.

6. 24-v alarm signal shown. For dry alarm contact, cut JW4 jumper and

dry contact will be available between AL1 and AL2.

7. Transformer secondary ground via Deluxe D board standoffs and

screws to control box. (Ground available from top two standoffs as
shown.)

8. Aquastat is supplied with unit and must be wired in series with the

hot leg to the pump. Aquastat is rated for voltage up to 277 v.

9. Blower motor is factory wired for high and low speeds. No other com-

bination is available.

10. The 460-v units using an ECM (electronically commutated motor) fan

motor, modulating HWR, and/or an internal secondary pump will
require a neutral wire from the supply side in order to feed the acces-
sory with 265-v.

TABLE 1

WIRE NUMBER

Blower

Speeds

1

2

3

4

5

Factory

HI + MED

BM(H) to

BR2(6)

BM(R) to

BR2(3)

BM(M) to

BR2(7)

Not Used

BR2(6) to

BR2(4)

HI + LOW

BM(H) to

BR2(6)

BM(R) to

BR2(3)

Not Used

BM(L) to

BR2(7)

BR2(6) to

BR2(4)

MED + LOW

BM(H) to

BR2(3)

BM(R) to

BR2(3)

BM(M) to

BR2(6)

BM(L) to

BR2(7)

BR2(2) to

BR2(4)

NOTES:
1. Status LED (GREEN) Slow Flash - Controller In - Fault Retry Mode. Fast Flash - Controller in Lock-

out Mode. Slow Flash = 1 Flash per every 2 seconds. Fast Flash = 2 Flashes per every 1 second.

2. Fault LED (RED) flashes a code representing last fault in memory. If no fault in memory code 1 is

flashed.

3. Cycles appropriate code, by cycling alarm relay in the same sequence as fault LED.
4. Alarm relay closes after 15 minutes.
5. Alarm relay cycles. Closed for 5 seconds and open for 25 seconds.

DELUXE D CONTROLLER FAULT CODES

OPERATION

STATUS LED

(GREEN)

TEST LED
(YELLOW)

FAULT LED

(RED)

ALARM

RELAY

Normal Mode

ON

OFF

Note 2

Open

Deluxe D is Non-Functional

OFF

OFF

OFF

Open

Test Mode

ON

Note 2

Cycle (Note 3)

Night Setback

Flashing Code 2

Note 2

Emergency Shut Down

Flashing Code 3

Note 2

Invalid Thermostat Inputs

Flashing Code 4

Note 2

No Fault in Memory

ON

OFF

Flashing Code 1

Open

HP Fault/(Lockout) Note 1

Slow Flash/

(Fast Flash)

OFF

Flashing Code 2

Open/(Closed)

LP Fault/(Lockout) Note 1

Slow Flash/

(Fast Flash)

OFF

Flashing Code 3

Open/(Closed)

FP1 Fault/(Lockout) Note 1

Slow Flash/

(Fast Flash)

OFF

Flashing Code 4

Open/(Closed)

FP2 Fault/(Lockout) Note 1

Slow Flash/

(Fast Flash)

OFF

Flashing Code 5

Open/(Closed)

CC Fault/(Lockout) Note 1

Slow Flash/

(Fast Flash)

OFF

Flashing Code 6

Open/(Closed)

Over-Under Voltage

Slow Flash

OFF

Flashing Code 7

Open (Note 4)

Normal Mode with UPS

ON

OFF

Flashing Code 8

Cycle (Note 5)

Swapped FP1/FP2 Lockout

Fast Flash

OFF

Flashing Code 9

Closed

Fig. 16 — Units with Deluxe D Controller, Three-Phase (460/575 V)